banner
Products
Integrated corporation
Clip Type Hall Effect Current Sensor of (C3) Linear

Clip Type Hall Effect Current Sensor of (C3) Linear

C3 series dismountable hall effect current sensor is an open loop device based on the measuring principle of the hall ef;
Basic Info.
Model NO. C3
Material Mixture
Accuracy Grade 0.5G
Application Switching Power Supply
IP Rating IP65
Certification ISO
Customized Customized
Insulation Voltage 2.5kv/50Hz/1min
Current Consumption 20+Is
Residual Voltage +-25mv
Thermal Drift of V0 +-1 Mv/C
Linearity 1
Usage Hall Sensor
Theory Hall Sensor
Output Analog Sensor
Supply Voltage +-12 _ +- 15
Transport Package Outer Carton with Smaller Inner Carton
Specification IEC 6044-1
Trademark HEYI
Origin Liushi, Yueqing, Zhejiang Province, China
HS Code 8542390000
Production Capacity 100000PCS/Year
Product Description
C3 series dismountable hall effect current sensor is an open loop device based on the measuring principle of the hall effect, with a galvanic isolation between primary and secondary circuit. It provides accurate electronic measurement of DC, AC or pulsed currents.

Clip Type Hall Effect Current Sensor of (C3) Linear


Electrical data (Ta=25ºC±5ºC,RL=2KΩ,CL=10000PF)
TypeC3-400AC3-600AC3-800AC3-1000AC3-2000AUnit
Rated current(Ipn)±400±600±800±1000±2000A
Measure range(Ip)0-±8000-±12000-±16000-±20000-±3000A
Rated output@Ip=±Ipn ±4±1%V
Supply voltage±12,±15V
Power Consumption<25mA
Offset voltage@Ip=0 ±20mV
Magnetic offset@Ip=±Ipn-0 ±20mV
Offset drift@ -40~+85ºC ≤±1mV/ºC
Output drift@ -40~+85ºC ≤±1mV/ºC
Linearity @Ip=0-±Ipn ≤1%FS
Response time@50A/μS, 10%-90% ≤5μs
Galvanic isolation@ 50HZ,AC,1min 5KV
Isolation resistance@ DC 500V 1000

Applications
·Variable speed drives
·Welding machine
·Battery supplied applications
·Uninterruptible Power Supplies (UPS)
·Electrochemical

Clip Type Hall Effect Current Sensor of (C3) Linear


Clip Type Hall Effect Current Sensor of (C3) Linear


Remarks:
1. All dimensions are in mm.
2. General tolerance ±1mm.
3. Elucidation: 1:+15V 2:-15V 3:V0UT 4:0V

Directions for use
1. When the current will be measured goes through a sensor, the voltage will be measured at the output end.(Note: The false wiring may result in the damage of the sensor)
2. Custom design in the different rated input current and the output voltage are available.

Standards
·UL94-V0.
·EN60947-1:2004
·IEC60950-1:2001
·EN50178:1998
·SJ 20790-2000

General date
ValueUnit
Operating temperature(TA)-40 to +85ºC
Storage temperature (TS)-40 to +125ºC
Mass(approx) (M)300g

Characteristics chart

Pulse current signal response characteristic:
Effects of impulse noise:

Clip Type Hall Effect Current Sensor of (C3) Linear

Clip Type Hall Effect Current Sensor of (C3) Linear

Send inquiry